Manual Transfer Panel
100A max Utility Main Breaker
30A-60A Generator Breaker
12 spaces with meters
For installations that require more capacity for heavier loads of 25 amps or more, such as electric water heaters, electric ranges, well pumps, motors, commercial refrigeration, heat pumps and central air conditioning. Suitable for use with larger generators. This panel may be sub-fed from the existing building panel, or may be used as service entrance equipment. Supplied with a double pole utility breaker and a double pole generator breaker that are interlocked to prevent both from being closed at the same time. This eliminates the danger of backfeeding to the utility, endangering utility repair crews. It also prevents utility power from feeding into your generator and causing damage. Allows manual transfer of individual loads to prevent overloading generator. The installer selects the the proper size branch breakers to add to this panel. Generator meters provided in panel.
The generator can be hardwired to this panel through a separately mounted inlet box. Or a PK series inlet can be mounted in a knockout to plug the generator cord directly into the bottom of this panel. The inlet box or PK inlet must be ordered separately.
Standard features include NEMA 3R outdoor suitable for surface or flush mounting and tin plated copper bus bars. Accommodates up to twelve 1 inch branch circuit breakers or as many as 20 combination 1/2 inch and 1 inch circuit breakers. This panel is UL Listed for use with any of the following circuit breakers:
- Siemens Type QP, QT, QPH, HQP, QPH, QPHF, QFP, QE, QEH
- Square D Series HOM (100 amp max)
- Westinghouse/Cutler Hammer Series BD, BR, BQ, GFC (100 amp max)
Provided with preinstalled generator breaker, main utility breaker and two meters for generator watts.
Assembled in USA![]()
General TRK Specs
Utility breaker ratings 30A to 100A Generator breaker ratings 30A to 60A Number of branch breaker spaces (1" each) 12 Maximum number of branch circuits
(using tandem/piggyback breakers)20 Enclosure types available NEMA 1 indoor & NEMA 3R outdoor Dimensions H x W x D (inches) 18 x 12-1/2 x 5
Specs and Ordering Table
Prices last updated 9/7/2025
Shipping weights start at 25 lbs. - dimensions 18x14x6 inches
These items normally ship in approximately 1 week or less.
Model No. | Utility Branch Breaker Required in Load Center (by installer) | Max. Generator Input
(Amps) (Watts) |
Male Inlet Installed (click link) |
Works with: Cordsets Inlet Boxes Inlet Kits |
Price $ US without branch breakers |
Add to Shopping Cart |
TRK0603CR | 60A | 30A 7,500W |
none (use PK30) |
PC3010M,
PC3020M, PC3025M or PC3040M PB30, PBN30 or PR30 PK30 inlet kit |
$321 |
|
TRK1003CR | 100A | 30A 7,500W |
none (use PK30) |
PC3010M,
PC3020M, PC3025M or PC3040M PB30, PBN30 or PR30 PK30 inlet kit |
$379 |
|
TRK1005CR | 100A | 50A 12,500W |
none (use PK50) |
PC5010,
PC5020, PC5025, PC5040
or PC5050 PB50, PB50N or PR50 PK30 inlet kit |
$380 |
|
NOTES:
1. A branch breaker provided by the installer must be installed in the upstream load center to feed this sub-panel.
2. Additional models with other breaker combinations available upon request.