VTS02001240SX
DISCONTINUED BY MANUFACTURER
SEE OTHER ALTERNATIVES AT THIS LINK
Automatic Transfer Switch
200 amp, 120/240V, 1-phase
generator exerciser
When you require a complete basic automatic transfer transfer switch, we have the solution. The Ronk Vigilant series is designed to UL 1008 and has all the necessary delay timers, voltage sensing, frequency sensing, and generator programmable exerciser clock. Assembled in USA
.
DESCRIPTION
The Ronk Vigilant® Automatic Transfer Switch automatically transfers critical loads in the event of a power outage. All units come standard as NEMA 3R, UL listed 1008. The Vigilant® consists of a simple, rugged design while maintaining the flexibility required to meet the needs of residential, agricultural and commercial applications..
FEATURES
Galvanized Corrosion Protection
Standard on all Vigilant® enclosures – this duplex coated, galvanized G90 grade steel meets American Society for Testing and Materials (ASTM) standard A653, with a service life of more than twice that of regular steel.Exterior Accessability
The easy–to–use, 7–day exerciser clock gives full control over day and time. The exerciser clock and indicator lamps are both accessible from outside the transfer switch – no need to open the door.Logic Control Board
At the heart of every Vigilant® automatic transfer switch lies our logic control board. It provides transfer switch control function with simplicity, flexibility and durability. Features include:
— Powered from genset battery for isolation against line transients
— Integrated voltage and frequency sensing
— Adjustable transfer delays using on-board potentiometers2-Year Warranty
One of the best comprehensive parts warranties in the industry.Compare with the competition...
Ronk Vigilant® Series... | the competition... |
* galvanized steel enclosure - better corrosion resistance | * painted steel |
* voltage and frequency sensing on both sources | * no frequency sensing on utility source |
* voltage, frequency and time delay settings field adjustable | * some settings fixed at factory |
* interface on outside of enclosure
includes exerciser, no need to open door |
* must open door to program exerciser and perform other functions |
* standard 2 year warranty | * 1 year warranty standard, extra cost for 2 or 5 years if available |
* normally ships quick from stock | * 4 week lead time or longer |
Specifications
Switch Current Rating 200 amps, 2 pole Voltage Rating 120/240V, 1 phase, 60Hz standard (50Hz optional) Temperature Ratings 45C (113F) 100% current, derate at higher temperatures, do not exceed 70C (158F) Control Voltage Rating 9-30 Vdc (25 mA load at 12Vdc) Control Features (see note 1)
Setting adjustments made using DIP switches and potentiometers on controller circuit board. Details contained in Installation & User Manual.
KEY:
P.U. = pickup
D.O. = dropoutFunction Adjustable Range Factory Setting start time delay (TDES) 3-32 sec 13 sec transfer time delay (TDNE) 11-64 sec 21 sec retransfer time delay (TDEN) 9-256 sec 256 sec cool down delay (TDEC) 0-256 sec 256 sec neutral delay (600A switch & above) 0-64 sec 10 sec voltage sensing of utility 11-18% D.O. above/below
6-13% P.U. above/below18%
13%frequency sensing of utility 5-12% above/below 12% voltage sensing of generator 11-18% D.O. above/below
6-13% P.U. above/below18%
13%frequency sensing of generator 5-12% above/below 12% Exerciser Clock electronic design, field adjustable for 7 day exercising without load transfer Battery Charger not included (order separately if required) UL Withstand & Closing Ratings 25,000 Amps (consult factory for specific protective device requirements) Nominal Dimensions (H x W x D) 24" x 20" x 6" Weight 58 lbs. Warranty 2 year factory warranty
NOTES:
1) The start time delay prevents nuisance generator starts during momentary utility power variations; transfer time delay allows generator set to stabilize before load is applied; retransfer delay prevents needless power interruption if return of utility power is momentary; stop delay allows gradual generator set cool down; undervoltage sensing of utility supply provides reliable starting of generator set during brownout conditions.
2) This switch is not service entrance rated. This generally means that you need a service entrance rated disconnect between this switch and your utility meter.
Customers who purchased this product also ordered:
(click underlined words to see product pages)Battery charger BATTEND022
Are YOU ready for the next power outage?
We welcome your feedback or questions. Click here to contact us.
See our Terms & Conditions before using information or
ordering from this web site.
Copyright © 1999-2023 NoOutage.com LLC. All rights reserved.