Harris Hydroelectric Turbine Generator
adjustable P.M. alternator
with Pelton wheel & up to 4 nozzles

This hydroelectric battery charger uses a Harris cast bronze pelton wheel and an alternator in a powder coated aluminum housing.   This model is available with 1, 2 or 4 nozzles installed at the factory.   Nozzle(s) can be up to 1/2 inch in diameter.

Each hydroelectric system is custom-built to match your site specifications.  A flexible hose penstock with shut-off valves is included on machines ordered with more than one nozzle.  Valves are provided for all nozzles when ordering a multi-nozzle unit.  The hose connections to the nozzles allow for easy disassembly and/or tilting up the unit for inspection and cleaning.

The permanent magnet brushless alternator comes with a mechanical field adjustment.  This alternator is 15-30% more efficient than the old Motorcraft alternator, produces less heat, and therefore lasts longer.  Click here for the kit to upgrade the old Ford Motorcraft alternator.

This unit will run for years before bearings need to be replaced.  The old Motorcraft alternator uses the commonly available #6203 sealed ball bearing along with one #NB-1 needle bearing.  These can be purchased at many auto parts stores.

Maximum achievable power output is 750 Watts for 12Vdc systems and 1500 Watts for 24Vdc systems.  The maximum output for the Permanent Magnet Alternator is 1500 Watts.  Order fan option below for systems operating above 500 Watts.  Made in USA  

 

OUTPUT IN WATTS & EFFICIENCY IN %
WITH RECOMMENDED NOZZLE SIZE
versus head and flow
Note that permanent magnet alternator is more efficient and usually produces more output.
(Permanent Magnet Table updated 7/6/2008)

FLOW
GPM

PERMANENT MAGNET ALTERNATOR
1500 WATTS MAX
  FORD ALTERNATOR (DISCONTINUED)
MAX: 750W @ 12V, 1500W @ 24V, 2500W @ 48V

NET (DYNAMIC) HEAD PRESSURE

NET (DYNAMIC) HEAD PRESSURE
25' 50' 75' 100' 200' 300' 25' 50' 75' 100' 200' 300'
11PSI 22PSI 33PSI 43PSI 87PSI 130PSI   11PSI 22PSI 33PSI 43PSI 87PSI 130PSI
3 - - - - 45W 42%
(1)3/32"
80W 49%
(1)3/32"
  - - - - 30W 28% 70W 43%
6 - 20W 37%
(1)7/32"
30W 37%
(1)3/16"
45W 42%
(1)5/32"
130W 60%
(1)5/32"
180W 56%
(1)1/8"
  - - 25W 31% 35W 32% 100W 46% 150W 46%
10 20W 44%
(1)5/16"
50W 56%
(1)1/4"
80W 59%
(1)1/4"
105W 58%
(1)7/32"
225W 63%
(1)3/16"
350W 65%
(1)5/32"
  - 35W 39% 60W 44% 80W 44% 180W 50% 275W 51%
15 35W 52%
(1)3/8"
85W 63%
(1)5/16"
115W 57%
(1)11/32"
170W 63%
(1)1/4"
350W 65%
(1)5/32"
520W 64%
(1)3/16"
  20W 30% 60W 44% 95W 47% 130W 48% 260W 48% 400W 49%
20 65W 72%
(1)7/16"
120W 67%
(1)3/8"
170W 63%
(1)11/32"
240W 67%
(1)5/16"
480W 67%
(1)1/4"
700W 65%
(1)7/32"
  30W 33% 80W 44% 130W 48% 200W 56% 400W 56% 550W 51%
30 100W 74%
(2)3/8"
175W 65%
(1)7/16"
270W 67%
(1)13/32"
360W 67%
(1)3/8"
675W 63%
(1)5/16"
1000W 62%
(1)5/16"
  50W 37% 125W 46% 210W 52% 290W 54% 580W 54% 850W 52%
50 150W 67%
(3)13/32"
310W 69%
(2)7/16"
450W 67%
(2)3/8"
620W 69%
(2)11/32"
1100W 61%
(1)7/16"
1500W 56%
(1)3/8"
  115W 51% 230W 51% 350W 52% 500W 56% 950W 53% 1400W 52%
100 300W 67%
(4)1/2"
560W 62%
(4)13/32"
850W 63%
(3)7/16"
1100W 61%
(3)13/32"
1500W 42%
(2)7/16"
-   200W 44% 425W 47% 625W 46% 850W 47% 1500W 42% -
200 - 725W 40%
(4)5/8"
1050W 39%
(4)9/16"
1300W 36%
(4)1/2"
- -   - 520W 29% 850W 31% 1300W 36% - -
                           
  1 NOZZLE BEST 2 NOZZLES BEST   3 NOZZLES BEST 4 NOZZLES BEST

The background colors in the table above indicate the approximate number of open nozzles that will give the best operating efficiency.  To achieve intermediate nozzle sizes order the next smaller size and drill it out.  For more nozzle information click here.

Please tell us your head, flow, pipe size and length, and battery voltage when ordering.

DC cable length and voltage drop must be evaluated carefully when laying out system.  Click here for our simple voltage drop calculator.

 

Customers who purchased this product also ordered:
(click underlined words to see product pages)
Pressure gauge PRESSGAUGE
Spare nozzles HARRIS-NOZ
Spare pelton wheel HARRIS-RUNR
Diversion load DLOAD-AIR, DLOAD-WTR
Diversion load controller of proper voltage & current rating such as C-35, C-40, C-60.
Inverter for Off-grid MS-SERIES or FX-VFX, or grid-tie GTFX-GVFX operation.
Battery bank.

 

 

 

Are YOU ready for the next power outage?

 1 Videos
 2 Outage Archives
 3 Utility Industry
 4 Why You Need Backup
 5 Personal Stories
 6 NoOutage Configurations
 7 Safety
 8 Sizing for Your Needs
 9 Voltage Drop Calculator
10 Test Reports
11 Placing Order
12 Equipment Leasing
13 Books & Videos  
14 Financing
15 Frequently Asked
16 Future Technologies
17 Electricity Glossary
18 Help with Plug Types
19 Who We Are
20 Why Buy Here
21 Our Customers
22 Pick a Contractor
23 Privacy Promise
24 Safe Shopping Guarantee
25 Terms & Conditions
26 What's New
27 Contacting Us
28 Parts Lookup
29 Parts & Service
30 Made in USA
31 Links

We welcome your feedback or questions.  Click here to contact us.
See our Terms & Conditions before using information or ordering from this web site.
Copyright © 1999-2023 NoOutage.com LLC.  All rights reserved.